Rf directional thruline watt meter model 43 user manual

The items are as they come from the closed airplane stores we acquire. Thruline 4410201, thruline 4410a501, thruline 4410026, thruline 4410 series, thruline 4412a101, thruline. The model 43 thruline wattmeter is an insertiontype rf wattmeter, designed to measure power flow and load match in 50 ohm coaxial transmission lines. It will accurately measure rf power under any load. Bird thruline rf directional wattmeter, model 43, complete with slugs. This is the manual for the bird 4360 hf and 4362 vhf rf directional wattmeters thruline style that were manufactured for the ham radio market under the name hammate. The meter provides direct readings in watts with an expanded scale for easy reading. Thruline 4410a500 measuring instruments pdf manual download. The model 43, when used in 50 ohm applications, has. Usb with a windows application, moving the display and user interface.

Refer to the schematic diagram in figure 31 for this description. This instruction book is arranged so that the essential information about safety is in the front of the book. When inquiring about updates to this manual refer to the part number and revision on the title page. Page 01 front cover page 02 picture page 03 summary sheet page 04 table of contents page 05 picture 10 page 06 section 1 general description 11 page 07 section 2 theory of operation 21 page 08 section 3 installation 31 page 09 installation 32. About this manual this instruction book covers rf directional thruline wattmeters models. Bird model 43 thruline rf directional wattmeter instruction. The bird electric corporation thruline model 43 rf directional wattmeter is designed with portability, featuring an attached carrying strap. Bird 4311 4314 thruline directional rf wattmeter ww. This instruction book covers thruline rf directional wattmeters models.

Wide band capability and dynamic range allows operation without elements, inserts, or bandswitching. Bird model 43 wattmeter, bird wattmeters, bird wattmeter. Rf directional thruline wattmeter model 43 also covers models 4431, 43p and series 4300 and 4520. With a bird 43 wattmeter, only two plugin elements would be required for these calibrations type 25a and 250a, i. The remainder of this instruction book is divided into. Bird 43 wattmeter, 9 elements, manual, leather case, very nice clean it worth. Bird 4304 rf directional multi range dual mode thruline wattmeter 1982 ww. Bird model 43 manual keyword found websites listing. Changes to this manual we have made every effort to ensure this manual is accurate. Bird 4111 series rf directional thruline wattmeter 1990.

The model 4314b thruline wattmeter is an insertion type rf wattmeter designed to measure power flow and load match in 50 ohm coaxial transmission lines. Bird model 43 thruline rf directional wattmeter instruction book. It is used to measure rf power when inserted into a transmission line of 50 ohms impedance. About this manual this manual covers the operating and maintenance instructions for the following models. The model 44d rf digital wattmeter is a compact, versatile test instrument used for direct measurement of forward and reflected rf power in a coaxial transmission line under any load conditions. The bird 4520 series comes ready for panel mounting. This manual covers the operating and maintenance instructions for the follow. Differences are discussed in chapter 6, on page 27.

This instruction book is arranged so that essential safety information appears in the front of the book. Bird model 43 thruline wattmeter kit voltage testers with a fullscale accuracy of 5%, the model 43 thruline wattmeter is a fieldproven portable, directional thruline wattmeter model 43 dx store there appeared to manual of rendering with pen and ink the thames and hudson manuals pdf epub mobi. Bird model 43p thruline rf wattmeter peakavg kit newwith pelican 1200. Thruline rf directional wattmeters portable wattmeters model 43 portable wattmeter power range 100 mw 10 kw using bird plugin elements. The bird model 43 is the industry standard for power measurements with a wide selection of elements available to cover. The model 43 wattmeter provides the user with direct readings in watts. Bird model 43 wattmeter vi about this manual this instruction book covers rf directional thruline wattmeters models. New listing bird rf directional thruline wattmeter model 43 manual instruction book vintage. The meter movements in the bird model 43 rarely fail and it is usually obvious when they do. View and download bird thruline 4410a500 instruction book online. The model 43 wattmeter can also be used in horizontal and vertical applications, while still providing an accurate reading.

It will accurately measure rf power under any load condition. Bird thruline 4342 rf directional dual wattmeter vswr monitor. Rf directional thruline wattmeter apm16 mhz electronics. Bird thruline model 43 watt meter with 27 pep kits as. Introduction describes the features of the 43 wattmeter, lists equipment supplied and optional equipment, and provides powerup instructions. The manual is arranged so that essential safety information appears in the front of the book. The 43 wattmeter is a fieldproven portable, insertiontype instrument designed to measure both forward and reflected cw power in coaxial transmission lines under any load condition. The bird 4431 rf sampling wattmeter is the same as the bird model 43 thruline wattmeter except for an rf signal sampler probe. Rf directional thruline wattmeter model 43 repeater builder. This instruction book is arranged so that essential information on safety appears in the front of the book.

Thruline wattmeter an wattmeter, designed match in i t 43, vswr less l. Wide band capability and dynamic range allows operation without elements, inserts, or. Bird 4304a thruline wattmeter vi about this manual this instruction book covers the bird 4304a rf thruline wattmeter. Warning you can damage your wattmeters meter movement in this step if you are not careful. About this manual this instruction book guides the user through the operation and maintenance of the bird model 4314b rf directional thruline wattmeter. Bird 430021 thruline rf directional wattmeter mfg 1957 for. Bird 43 thruline wattmeter rf connector n female 4240062 to uhf male 4240179. Two models have rf sampler ports, while the bird 43p can measure peak power. Elements are available in a variety of power and frequency ranges see the bird electronic corporation catalog for details. This test is optional, you can repairdiagnose your watt meter without this test. It is capable of accurately measuring legacy analog modulated signals as well as signals modulated with the newest digital modulation schemes.

This manual covers the operation of the bird 43 thruline wattmeter and its. Bird instruction manual for model 43 thruline rf directional wattmeter ebay. Specifications are from advanced energy and may vary slightly due to upgrades, options, or revisions this unit may or may not have. It is intended for use on cw, am, fm, and tv modulation envelopes, but not pulsed modes. Index of technical information for bird technologies rf test. Bird 4304a rf directional thruline wattmeter instruction manual 387 kb pdf bird 4360 and 4362 hammate wattmeter manual 1. These are provided to assist the user in formulating acceptance criteria, determining applications, and for periodic recalibration of the instrument. Bird thruline 4342 rf directional dual wattmeter vswr monitor comes with a manual and what you see in the pictures. The scale is graduated for 25, 50, and 100 full scale. Literature contents chapter layout introduction describes the features of the 43 wattmeter, lists equipment supplied and optional equipment, and provides powerup instructions.

This manual covers the operation of the bird 43 thruline wattmeter and its descendants. Find great deals on ebay for wattmeter rf and rf watt meter. This rf probe provides a low power sample of the signal being measured and is available at a female bnc connector on the right side of the housing. This item is used equipment and we are selling this item without warranty or return. The telewave model 44a rf wattmeter is a compact, versatile instrument used for direct measurement of forward and reflected rf power in a coaxial transmission line under any load conditions. The bird electric corporation thruline model 43 rf directional wattmeter is an insertiontype rf wattmeter that is designed to measure rf power and load match in 50 ohm coaxial transmission lines. Vintage rca institutes rf af signal generator works 170kc50mc user manual more. Thruline 43 measuring instruments pdf manual download. With a fullscale accuracy of 5%, it accurately measures rf power with low added vswr and insertion loss.

Bird thruline 4410a500 instruction book pdf download. When used in 50 ohm applications, the 43 has a maximum vswr of 1. The bird model 43 is the industry standard for power measurements with a wide selection of elements available to cover a wide choice of frequency ranges and power ranges. Bird 43 thruline wattmeter sales, rent, calibration. Thruline rf directional wattmeter instruction book. Bird model 43 thruline rf wattmeter kit w 10c element and 25w rf load.

It is intended for use on cw, am, fm, ssb, tv, and pulse signals only. Each model 43 consists of a line section, qc quick change connectors and an indication. An introduction, overview and howtouse tutorial of the venerable bird model 43 thruline directional rf wattmeter power meter. It is a device which requires no external power source or batteries for operation. Manuals and softfirmware updates available at model. Bird model 43 wattmeter vi rf voltage may be present in rf element socket keep. Theory of operation describes how the 43 wattmeter works and. Rf directional wattmeters model 43, accessory guide the model 43 thruline directional wattmeter accurately measures forward or reflected power in coaxial transmission lines under any load condition. View and download bird thruline 43 instruction book online. Bird model 43 rf wattmeter repairs and tips by martin rf supply. Index of technical information for bird technologies rf. Rf a the 14 on wlth to a rf in any the so that catch the cut air une matc rsc may bird corp. On this page you can read or download wattmeter disadvtage in pdf format.

Get the best deals on bird model 43 when you shop the largest online selection at. Bird model 43 thruline rf directional wattmeter instruction guide manual. The bird model 43 thruline directional wattmeter is a portable insertiontype instrument for measuring forward and reflected power in coaxial transmission lines. Page 01 front cover page 02 picture page 03 summary sheet page 04 table of contents page 05 picture 10. The bird model 43 thruline directional wattmeter is a fieldproven portable, insertiontype instrument designed to measure both forward and reflected cw power in coaxial transmission lines under any load condition. Each model 43 consists of a line section, qc quick change connectors and an indication meter housed in a rugged, corrosionresistant. Thruline 43, thruline 43p, thruline 4431, thruline 4300a, thruline 4301, thruline 4521, thruline 4527, thruline 4522. It is intended for use with cw, am, fm, and tv modulation, but not pulse modulation.

If you discover any errors, or if you have suggestions for improving this manual, please send your comments to our solon, ohio factory. Bird electronics model 4410 rf thruline directional wattmeter, new condition. Bird electronic corporation thruline 43 rf directional. Reading the safety precautions section before operating the equipment is strongly advised. Chapter 1 introduction purpose and function the model 4308 thruline wattmeter is a portable multirange rf wattmeter. Bird model 43 rf wattmeter repairs and tips by martin rf. Rf directional thruline wattmeter bird technologies. Page 02 picture page 03 summary sheet page 04 table of. The bird 43 was introduced in 1952, and is still being produced. The 43 is an insertiontype rf wattmeter, designed to measure rf power and load match in 50 ohm coaxial transmission lines. Reading the safety precautions section before operating the equipment is strongly.

This instruction book covers rf directional thruline wattmeters models. Details about bird rf directional thruline wattmeter model 43 manual. We answer all questions and will provide many detailed photos, simply email us. Bird 43 instruction book makes it easy to find manuals. This instruction book covers the series 4410 rf directional thruline wattmeter. The model 43 wattmeter is intended to to be used with cw, am, fm, and tv modulation. If you dont see any interesting for you, use our search form on bottom v. New listingbird electronics 100e thruline wattmeter element 010w 400mhz for model 43. Get the best deals on rf wattmeter when you shop the largest online selection at. Simple thruline style operation for instant forward or reflected power readings. The 4360 is rated at 200w low range or 2000 watts, and from 1.

1270 84 421 1126 1205 974 771 1509 592 746 1200 621 193 1289 1185 737 896 988 401 1069 1319 284 1357 145 894 1157 832 1095 747 1441 864 1518 1224 353 1261 303 1001 21 766 242 664 1200 1273 185 223 430 300